Mantis Bugtracker
  

Viewing Issue Simple Details Jump to Notes ] View Advanced ] Issue History ] Print ]
ID Category Severity Reproducibility Date Submitted Last Update
0004699 [Squeak] Morphic minor always 09-03-06 05:41 09-06-06 00:09
Reporter wiz View Status public  
Assigned To
Priority normal Resolution open  
Status new   Product Version 3.9
Summary 0004699: [Bug] In 7055 Collapsing a tilted System Window does not update the screen correctly.
Description For this one.

Get a workspace.
Uing the blue halo tilt it 30-45 degrees.
Now press the collapse button on the workspace title.

Where did it go?

Open and close a world menu near the top left of the display window.

If you have done this in the right place you will see a tilted collapsed workspace window.

Pressing the (un)collapse button on the window restores the tilted workspace to its original position.
Additional Information This is freshly discovered so I have not checked how far back this problem goes. It has the feel of an oldie.

The problem is obviously that the damaged rectangle in the location of the collapsed tilted workspace is not getting updated properly.

See also 0004677 for another collapse related bug.
Attached Files  SystemWindow-c...pseOrExpand.st [^] (1,518 bytes) 09-06-06 00:04

- Relationships
child of 0005124new  SystemWindows is ripe for a refactoring. 

- Notes
(0006895 - 228 - 264 - 264 - 407 - 407 - 407)
wiz
09-06-06 00:09

Uploaded SystemWindow-c...pseOrExpand.st

Which fixes the problem by adding a 'self changed' at the appropriate time and place.

It fixes the symptom for this one bug.

see 0004700 for more difficulties with system windows.
 

- Issue History
Date Modified Username Field Change
09-03-06 05:41 wiz New Issue
09-06-06 00:04 wiz File Added: SystemWindow-c...pseOrExpand.st
09-06-06 00:09 wiz Note Added: 0006895
09-20-07 06:04 matthewf Relationship added child of 0005124